6501-J007A |
P-1000 20W6 Halogen lamp assembly option |
|
6501-M016A1 |
P-1000 Hg-360ES1 External mercury lamp attachment
Including: Lamp housing, power supply and 577nm, 546nm, 435nm and 405nm filters. |
|
6501-J114A |
P-1000 QPA-4 Rotatory plate, approx.-20 degree |
|
6501-J020A |
P-1000 SHP-101 Sample sipper - specifications:-
Suction time 0 to 999.9 seconds, Drain time 0 to 999.9 seconds, Delay time 0 to 999.9 seconds, flow cell light pathlength 100mm, inside diameter 5mm, cell capacity 2ml, cell material glass, carryover 0.5% (under optimum conditions), minimum sample volume 5ml. |
|
6501-J013A |
P-1000 QPA-3 Rotatory plate, approx.+20 degree |
|
6501-M018A |
P-1000 Hg-360PS External mercury lamp attachment
Including: Lamp housing and power supply. |
|
6501-J011A |
P-1000 QPA-1 Rotatory plate, approx.+2 degree |
|
6501-M016A |
P-1000 Hg-360ES External mercury lamp attachment
Including: Lamp housing, power supply and 577nm, 546nm, 435nm and 365nm filters |
|
6501-J012A |
P-1000 QPA-2 Rotatory plate, approx.-2 degree |
|
6501-J021A |
P-1000 PTC-102 Peltier thermostatted rectangular cell holder for up to 100mm pathlength cells. Heating cooling by Peltier effect with thermistor temperature sensor (Holder and inside the cell). Temperature setting 15°C to 40°C (when the room temperature is at 20°C). Temperature control ±0.3°C, temperature accuracy ±1°C. Temperature setting error ±1°C (Difference between the displayed temperature and the set temperature) |
|
1103-1106A |
P-Series Cylindrical glass cell - 3.5 x 50 mm |
|
1103-1105A |
P-Series Cylindrical glass cell - 3.5 x 100 mm |
|
1103-1101A |
P-Series Cylindrical glass cell - 10 x 100 mm |
|
1103-1136A |
P-Series Cylindrical glass cell - 10 x 50 mm |
|
1103-1134A |
P-Series Cylindrical glass cell - 10 x 10 mm |
|
1103-1133A |
P-Series Cylindrical glass cell - 3.5 x 10 mm |
|
1103-1021A |
P-Series Cylindrical quartz cell 10mm ID x 100mm |
|
1103-1161 |
P-Series Cylindrical quartz cell for V-shaped cell holder10mm ID x 0.2mm |
|
1103-1160 |
P-Series Cylindrical quartz cell for V-shaped cell holder 10mm ID x 0.1mm |
|
1103-1141A |
P-Series Cylindrical quartz cell 3.5mm ID x 10mm |
|
1103-1163 |
P-Series Cylindrical quartz cell for V-shaped cell holder10mm ID x 1mm |
|
1103-1164 |
P-Series Cylindrical quartz cell for V-shaped cell holder 10mm ID x 2mm |
|
1103-1162 |
P-Series Cylindrical quartz cell for V-shaped cell holder 10mm ID x 0.5mm |
|
1103-1004 |
P-Series Cylindrical quartz cell for V-shaped cell holder 20mm ID x 20mm |
|
1103-1002 |
P-Series Cylindrical quartz cell for V-shaped cell holder 20mm ID x 50mm |
|
1103-1022A |
P-Series Cylindrical quartz cell 10mm ID x 50mm |
|
1103-1024A |
P-Series Cylindrical quartz cell 10mm ID x 10mm |
|
1103-1025A |
P-Series Cylindrical quartz cell 3.5mm ID x 100mm |
|
1103-1026A |
P-Series Cylindrical quartz cell 3.5mm ID x 50mm |
|
1103-1001 |
P-Series Cylindrical quartz cell for V-shaped cell holder 20mm IDx100mm |
|
1103-1165 |
P-Series Cylindrical quartz cell for V-shaped cell holder 10mm ID x 5mm |
|
1103-1114A |
P-Series Jacketed cylindrical glass cell - 3.5 x 50 mm |
|
1103-1109A |
P-Series Jacketed cylindrical glass cell - 10 x 100 mm |
|
1103-1113A |
P-Series Jacketed cylindrical glass cell - 3.5 x 100 mm |
|
1103-1112A |
P-Series Jacketed cylindrical glass cell - 10 x 10 mm |
|
1103-1110A |
P-Series Jacketed cylindrical glass cell - 10 x 50 mm |
|
1103-1116A |
P-Series Jacketed cylindrical glass cell - 3.5 x 10 mm |
|
1103-1033A |
P-Series Cylindrical quartz cell (thermostattable) 10mm ID x 50mm |
|
1103-1032A |
P-Series Cylindrical quartz cell (thermostattable) 10mm ID x 10mm |
|
1103-1029A |
P-Series Cylindrical quartz cell (thermostattable) 3.5mm ID x 10mm |
|
1103-1031A |
P-Series Cylindrical quartz cell (thermostattable) 3.5mm ID x 100mm |
|
1103-1030A |
P-Series Cylindrical quartz cell (thermostattable) 3.5mm ID x 50mm |
|
1103-1034A |
P-Series Cylindrical quartz cell (thermostattable) 10mm ID x 100mm |
|
6147-J145A |
RCH-20 J-700 Series and P-Series Holder for rectangular cells up to 20 mm path length with spacers. |
|
6501-J009A |
P-Series HPLC Flow cell - 3.5 x 50 mm |
|
6501-J008A |
P-Series HPLC Flow cell - 1 x 50 mm |
|
6501-M017A |
V-Shaped cell holder for J-Series cylindrical cell (cylindrical cell for CD/ORD can be mounted on this holder). |
|
1103-2001A |
P-Series Flow through cell - 3.5 x 50 mm |
|
1103-2002A |
P-Series Flow through cell - 10 x 100 mm |
|
1904-6001A |
P-Series Thermostattable holder for rectangular cells up to 20 mm path |
|
4340-0016 |
Photomultiplier detector R928 |
|
5330-0099 |
P-1010 Halogen lamp RJ-2012, 20W |